The service inspector asked to have the system pressurized with compressed air. The test pressure was set at between 25 to 30 psi. The inspector used an ultrasound detection instrument that sensed ultrasound emissions produced by a leak. The instrument then translated these sounds down from the high frequency range. Through headphones supplied with the instrument, the inspector was able to hear the low frequency or "audible" range where the sounds were coming from and see intensity increments via a display panel on the back of the instrument.

While scanning the first section with this ultrasonic instrument, the inspector noted that a 250 lb steam line close by was creating excessively loud ultrasound. Since it was anticipated that the leak sound would have to penetrate through the insulation and would be substantially lower in volume than the steam generated noise, the inspector requested that the steam line be temporarily turned off.

After the steam line was shut off, the inspector used a module to sense airborne ultrasounds, referred to as a scanning module, and located three leaks. The leaks were repaired (welded) within a few hours. The inspector then noted a drop of pressure in the system pressure gauge and determined that there were still more leaks to find. He resumed scanning the pipe system with his ultrasound instrument but was unable to identify any more leaks.

Speaking of pressure, the customer was depending on the inspector to find all the leaks before the evening shift began. He asked for permission to make test points in the insulation by perforating the aluminum skin with a sharp screwdriver. Out of necessity, permission was granted. The inspector made a series of strategic perforations on each side of the 8" piping system.

He switched to a module used to inspect structure borne ultrasounds called a stethoscope or "contact" module. This is a module with a solid metal rod on the end that acts as a wave guide to transfer structure borne ultrasounds produced by the leak to the instrument's sensor. He carefully inserted the wave-guide into the holes he fashioned and listened for any increases in the sound. It was not until the inspector came up to an elbow in the system that he heard what he believed was the source of the problem. The insulation was removed and to everyone's relief and the leak was confirmed. The problem became evident.

Although the majority of the system was constructed in 316 stainless steel, the elbow was not. To temporarily fix the leak, soft putty that hardens in less than 10 minutes was fashioned over the leak. It was hypothesized that because the system was pulling vacuum, the putty would be sucked into the leak site just enough to stop the leak. While the system was changed from positive to negative pressure, the inspector made a final scan. Their supposition was correct. All of the leaks had been identified and repaired, and the customer could resume their process.

The inspector has checked back several times and confirmed that the customer was able to run his process for the two weeks necessary to have the part fabricated. For Enercheck Systems, it was just another success story using ultrasound detection equipment to spot leaks. For the customer, it kept order fulfillment on track - potentially saving hundreds of thousands of dollars in downtime.

Article submitted by:

Bruce Gorelick, vice president, Enercheck Systems, Charlotte, N.C., www.enerchecksystems.com
Alan Bandes, vice president marketing, UE Systems, Inc., www.uesystems.com

Upcoming Events

August 8 - August 10, 2023

Maximo World 2023

View all Events
banner
80% of Reliabilityweb.com newsletter subscribers report finding something used to improve their jobs on a regular basis.
Subscribers get exclusive content. Just released...MRO Best Practices Special Report - a $399 value!
DOWNLOAD NOW
IMC-2022 Who's Who: The World's Best Run Companies

The International Maintenance Conference (IMC) provides a fresh, positive community-based curated experience to gain knowledge and a positive perspective for advancing reliability and asset management through people, their managers, the strategy, the processes, the data and the technology.

Uptime Elements Root Cause Analysis

Root Cause Analysis is a problem solving method. Professionals who are competent in Root Cause Analysis for problem solving are in high demand.

Reliability Risk Meter

The asset is not concerned with the management decision. The asset responds to physics

Why Reliability Leadership?

If you do not manage reliability culture, it manages you, and you may not even be aware of the extent to which this is happening!

Asset Condition Management versus Asset Health Index

Confusion abounds in language. Have you thought through the constraints of using the language of Asset Health?

Seven Chakras of Asset Management by Terrence O'Hanlon

The seven major asset management chakras run cross-functionally from the specification and design of assets through the asset lifecycle to the decommissioning and disposal of the asset connected through technology

Reliability Leader Fluid Cleanliness Pledge

Fluid Cleanliness is a Reliability Achievement Strategy as well as an asset life extension strategy

MaximoWorld 2022 Conference Austin Texas

Connect with leading maintenance professionals, reliability leaders and asset managers from the world's best-run companies who are driving digital reinvention.

“Steel-ing” Reliability in Alabama

A joint venture between two of the world’s largest steel companies inspired innovative approaches to maintenance reliability that incorporate the tools, technology and techniques of today. This article takes you on their journey.

Three Things You Need to Know About Capital Project Prioritization

“Why do you think these two projects rank so much higher in this method than the first method?” the facilitator asked the director of reliability.