Flake Breaker Vibration Analysis Case Study

Route Data clearly shows the bearing defect in the spectrum

Route Data clearly shows the bearing defect in the spectrum. Bottom spectrum was taken after the Flake Breaker bearing where changed out.

Bearing Defect Impacting Occurring in the Peak Vue Spectrum

Bearing Defect Impacting Occurring in the Peak Vue Spectrum. Top Spectrum was taken after the new bearings where installed. Impact has decreased.

11 Months of Trend Data of the High Frequency Band

11 Months of Trend Data of the High Frequency Band. Clearly show the rapid decrease after the bearing where replaced.

Route Data Spectrum before and After New Bearings replaced

Work Order Summary